SVContact

DEEP DIVE · SOURCE-BASED GUIDANCE

EBC batches and representative sampling

The batch links process, analysis, quantity and customer. If that link is weak, the certification evidence is weak.

Editorial update: Requirements and methodology versions: see sources below
Batch definition → Increments → Composite sample → Laboratory report
A practical working structure from Biocharking.

A batch is a defined production period

An EBC production batch starts when registered in the Biochar Tool and receives a unique ID and QR code. It may last no more than 365 days, including interruptions. Several batches may run during one year when feedstock or production conditions differ. Interruptions and production time must be recorded, and produced quantities reported at least quarterly. [1]

Allowed variation is not uncontrolled variation

The standard summary permits pyrolysis temperature and feedstock-composition variation under defined 20% rules. This does not prove that every product inside the limits is homogeneous. Process monitoring must still demonstrate that biochar quality does not vary materially within the batch. [1]

Representativeness is built over time

A grab sample from one bag or production day does not automatically represent annual output. The sampling plan should define location, frequency, increment size, combination, homogenisation, reduction, sealing, identity and retention samples. The endorsed sampler follows the plan agreed during technical pre-audit. [2]

Practical data model

  • batch ID, date and time;
  • feedstock category, delivery or silo;
  • production line and operating state;
  • relevant temperatures and residence-time indicators;
  • quantity produced and inventory movement;
  • increment ID, sampler and composite-sample link.

This allows deviations to be investigated without reconstructing relationships after the event.

Define the batch boundary before interpreting the analysis

Record the feedstocks, line and process conditions covered by the batch. Connect each operating record and sample with the same identity. An internal number may sit alongside the official batch ID, but their relationship must be unambiguous.

When feedstock composition or operating conditions change, document the assessment. Record what changed, when it happened and the decision to continue or create a new batch. Relabelling later cannot repair an unclear production boundary.

What a sampling record needs to show

Suggested fields for the producer’s sampling journal
Field groupExample information
IdentityBatch ID, increment ID and composite-sample ID.
Time and placeDate, time, operating period and sampling location.
ExecutionSampler, applicable plan version and quantity.
HandlingCombining, homogenisation, reduction and sealing.
Storage and analysisRetention-sample location, dispatch and laboratory sample number.
DeviationDeparture from the plan, affected period and recorded decision.

This is a practical journal structure. Frequency, quantities and execution must come from the sampling plan applicable to your production.

Fictional example: a changed feedstock delivery

A producer starts batch EX-B01 on 1 September 2026 and receives a new delivery into silo EX-S02 on 12 September. Origin and receipt date are recorded. Feeding starts on 13 September at 09:00; the time is marked in the operating journal. Quality personnel assess the change against the batch definition and record the decision.

Increments from the period receive individual identities and a connection with the correct batch and plan version. When the composite sample is sent to the laboratory, the links between increments, composite sample and report number remain. This example illustrates traceability; it sets no universal sampling frequency or approved batch change.

In the fictional sampling chain, increment EX-D03 belongs to plan version EX-P02 and composite sample EX-SP01. The composite is dispatched on 21 September and receives fictional laboratory number EX-LAB01.

Check the chain in both directions

Start with the laboratory sample number and follow the chain back to operation and feedstock. Then start with an operating period and identify the samples representing it. A missing link in either direction calls for a better procedure.

Download an empty sampling journal as CSV. Adapt it to your plan or use it to structure records in Pyrolog. This is a documentation aid, not an official EBC form.

View a row with entirely fictional records. Also see laboratory-report interpretation and documentation and stock reconciliation.

Version control

Always verify the latest original version before an audit, contract, investment decision or authority contact.

Claim-level sources

  1. StandardEuropean Biochar Certificate Standard 10.5E, 15 September 2025 ↗
  2. Method guidanceEBC analytical methods and laboratory guidance ↗
← Back to topic