Start with the sample

Check batch ID, sampling date, sampler, sample composition and condition on laboratory receipt. A representativeness error may exceed analytical uncertainty and cannot be repaired by additional decimal places.

Read the basis and units

Results may be expressed on dry matter, at 88% dry matter or as received. g/t and mg/kg are numerically related, but comparisons fail if the reference basis differs. Moisture, ash and inorganic carbon also affect values per tonne of delivered product.

H/Corg and O/Corg

H/Corg indicates carbonisation and may parameterise persistence under CRCF. EBC normally requires H/Corg below 0.7 and below 0.4 for FeedPlus. In 2026 CSI published a formal exemption route for certain ash-rich chars where total hydrogen may distort H/Corg. It is not permission to ignore a result without approval. [1] [2]

Functional parameters

WHC, solid electrical conductivity, pH, bulk density and BET describe different properties. EBC treats BET as an optional additional parameter, while WHC and solid electrical conductivity are in the basic package. High BET does not prove water retention, crop benefit or treatment performance. [3]

Decision model

  1. Verify sample and method.
  2. Verify units and reference basis.
  3. Compare against the correct class and version.
  4. Review trends across representative batches.
  5. Connect deviation to plausible feedstock or process causes.
  6. Document hold, re-test, investigation or release.

EBC limit values at a glance

Compare every result against the class you are actually certifying, and against the version that applies to the audit. Heavy metals are given in g/t (mg/kg) dry matter. [4]

Selected EBC 10.5 limits by class (g/t dry matter unless stated)
ParameterFeedPlusAgroOrganicAgroUrbanMaterials
H/Corg (molar)< 0.4< 0.7< 0.7< 0.7< 0.7
16 EPA PAH (g/t)6.0 (+2.4)6.0 (+2.4)6.0 (+2.4)declaredeclare
8 EFSA PAH (g/t)1.01.01.01.01.0
Pb5*45120120120
Cd0.5*0.71.51.51.5
Cu7070100100100
Ni2525505050
Hg0.1*0.4111
Zn200200400400400
Cr7070909090
As2*13131313
  • * FeedPlus values for Pb, Cd, Hg and As refer to 88 % dry matter, as in feed legislation.
  • 16 EPA PAH: the limit is 6 g/t with an analytical tolerance of 2.4 g/t.
  • Cu and Zn limits may be exceeded for products labelled and traded as micronutrient fertiliser.
  • O/Corg should be below 0.4 in all classes. PCB and PCDD/F become mandatory when 8 EFSA PAH exceed 1 g/t.

This overview is a working aid. The standard text, including later clarifications, always prevails.

Other rules may be stricter than the certificate

A product that passes EBC-Agro is not automatically an EU fertilising product. CMC 14 in the Fertilising Products Regulation sets its own limits, for example PAH16 at no more than 6 mg/kg dry matter, PCDD/F at no more than 20 ng WHO-TEQ/kg and REACH registration of the material. [5] Read the soil and growing-media article for the full comparison.

Version control

Always verify the latest original version before an audit, contract, investment decision or authority contact.

Claim-level sources

  1. StandardEuropean Biochar Certificate Standard 10.5E, 15 September 2025 ↗
  2. ClarificationCSI: Exemption from H/Corg criterion for ash-rich biochars, 8 July 2026 ↗
  3. Method guidanceEBC analytical methods and laboratory guidance ↗
  4. StandardEBC Guidelines version 10.5E (European Biochar Certificate) ↗
  5. EU lawDelegated Regulation (EU) 2021/2088 – CMC 14 pyrolysis and gasification materials ↗
← Back to topic