DEEP DIVE · REVIEWED ARTICLE
Biochar dust and ATEX
Fine biochar should be treated as a potential combustible-dust hazard until product-specific assessment shows otherwise.
When dust becomes an explosion hazard
A dust explosion requires combustible dust, air, sufficient dispersion, confinement and an effective ignition source. Mills, screens, filters, elevators and pneumatic transport may create several conditions simultaneously. Deposited dust may fuel secondary explosions if disturbed.
The ATEX process
Directive 1999/92/EC requires employers to assess explosive-atmosphere risks, classify areas where such atmospheres may occur and coordinate technical and organisational safeguards. Classification is based on probability and duration, not on whether an explosion has happened before. [1]
Data that may be required
- minimum ignition energy and ignition temperature;
- Kst and maximum explosion pressure;
- particle-size distribution and moisture;
- electrical resistivity and electrostatic charging;
- dust-layer thickness and housekeeping frequency.
Generic “charcoal” data are not always representative of the actual product.
Protection hierarchy
First prevent dust release and ignition. Then address grounding and bonding, suitable equipment, ventilation, housekeeping, detection, isolation, explosion venting or suppression where required. Respiratory PPE matters for exposure but does not prevent a process dust explosion.
Document changes
A finer fraction, lower moisture, new mill, higher conveying speed or different filter may change the hazard. Management of change should trigger reassessment. EBC also requires written communication of production hazards to workers. [2]
Zones and the explosion protection document
Directive 1999/92/EC divides dust areas into three zones and requires the employer to keep an explosion protection document that shows how risks have been assessed and what measures apply. [1]
| Zone | Definition | Typical biochar examples |
|---|---|---|
| Zone 20 | Dust cloud present continuously, for long periods or frequently | Inside mills, filters, silos and pneumatic conveying |
| Zone 21 | Dust cloud likely to occur occasionally in normal operation | Around filling points, bag emptying and open transfer |
| Zone 22 | Dust cloud unlikely in normal operation and short-lived if it occurs | Rooms with dust deposits that can be disturbed |
Equipment used in each zone must have a matching category under the ATEX product directive 2014/34/EU. The zones are examples – the classification must be based on your plant.
Test your own product rather than relying on generic values
Explosion data for charcoal vary widely with feedstock and particle size. A 2026 study of biomass charcoals reported a weak explosion for rubber-wood charcoal, with a minimum explosible concentration of 155 g/m³ and Kst of 35 bar·m/s, while coconut-shell and palm-kernel-shell chars showed no explosibility in the tests. [3] That is a reason to test the actual product and fraction you handle, not a reason to assume your char is harmless.
In Sweden
Since 1 January 2025, the Swedish rules on work in explosive atmospheres are found in chapter 9 of AFS 2023:10 Risker i arbetsmiljön, which replaced the former AFS 2003:3. [4]
Always verify the latest original version before an audit, contract, investment decision or authority contact.
Claim-level sources
- EU lawDirective 1999/92/EC – explosive atmospheres at work ↗
- StandardEuropean Biochar Certificate Standard 10.5E, 15 September 2025 ↗
- ResearchDewanto et al. (2026): dust explosion potential of biomass charcoal, E3S Web of Conferences 693 ↗
- Swedish regulationArbetsmiljöverket: AFS 2023:10 Risker i arbetsmiljön ↗
